MODEL |
Voltage
|
RMS Voltage Range |
1
x 30 V .. 300 V (500 V optional) |
PS
81xx |
(Phase - Neutral) |
3
x 30 V .. 300 V (500 V optional)
|
PS
83xx |
Resolution |
<
0.01 %
|
Stability |
<
0.005 % (integration time 150 s) |
Distortion Factor |
< 0.3 % |
|
0.2 % typical
|
PS
8xxxB |
Accuracy |
0.05 % |
PS
8xxxA |
|
0.02 %
|
PS
8xxxE |
|
0.01 % |
PS
8xxxS |
|
|
|
Current
|
RMS Current Range |
1
x 1 mA .. 120 A (240 A optional) |
PS
81xx |
|
3 x 1 mA .. 120 A
(240 A optional)
|
PS
83xx |
Resolution |
<
0.01 % |
Stability |
<
0.005 % (integration time 150 s) |
Distortion Factor |
<
0.3 % |
|
0.2 % typical |
PS
8xxxB |
Accuracy |
0.05
% |
PS
8xxxA |
|
0.02 % |
PS
8xxxE |
|
0.01 % |
PS
8xxxS |
|
Phase Angle |
Range |
0 °
.. 360 ° |
Resolution |
<
0.01 ° |
|
0.5 ° |
PS
8xxxB |
Setting Accuracy |
0.05 ° |
PS
8xxxA |
|
0.02 ° |
PS
8xxxE |
|
0.01 ° |
PS
8xxxS |
|
Frequency |
Fundamental Frequency Range |
40 Hz
.. 70 Hz |
Resolution |
<
0.002 Hz |
Accuracy |
< 0.002
Hz |
|
|
|
Output Power |
Current / Voltage
(standard configurations *)
|
60 VA / 60 VA ** |
PS
8x00 |
100 VA / 100 VA |
PS
8x01 |
300 VA / 300 VA |
PS
8x03 |
600 VA / 600 VA |
PS
8x06 |
1000 VA / 1000 VA |
PS
8x10 |
2000 VA / 2000 VA |
PS
8x20 |
|
Harmonics |
• Free programmable
• Preprogrammed test patterns according to Standard
IEC 1036
|
|
Interfaces |
RS 232
(IEEE 488 optional)
with SCPI compatible programming protocol
|
Output Protection |
Short
Circuit, Open Circuit, Thermal Muting,
Residual Current Device on Voltage output
|
Dimensions |
19"
Rack System |